authorKishon Vijay Abraham I <kishon@ti.com>2020-07-22 16:33:11 +0530
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2020-08-19 08:14:59 +0200
commite3e983b327e7f2456c6d72c7942dcbb1a91160af (patch)
tree906da713001d2410a9c83e6e312a102c61aca32a /drivers/pci/controller
parentf5a77bafe02c6c31be5883458b0cbce4c43ea4cd (diff)
PCI: cadence: Fix updating Vendor ID and Subsystem Vendor ID register
[ Upstream commit e3bca37d15dca118f2ef1f0a068bb6e07846ea20 ] Commit 1b79c5284439 ("PCI: cadence: Add host driver for Cadence PCIe controller") in order to update Vendor ID, directly wrote to PCI_VENDOR_ID register. However PCI_VENDOR_ID in root port configuration space is read-only register and writing to it will have no effect. Use local management register to configure Vendor ID and Subsystem Vendor ID. Link: https://lore.kernel.org/r/20200722110317.4744-10-kishon@ti.com Fixes: 1b79c5284439 ("PCI: cadence: Add host driver for Cadence PCIe controller") Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com> Signed-off-by: Lorenzo Pieralisi <lorenzo.pieralisi@arm.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/pci/controller')
-rw-r--r--drivers/pci/controller/pcie-cadence-host.c9
1 files changed, 7 insertions, 2 deletions
diff --git a/drivers/pci/controller/pcie-cadence-host.c b/drivers/pci/controller/pcie-cadence-host.c
index ec394f6a19c8..ae7affcb1a81 100644
--- a/drivers/pci/controller/pcie-cadence-host.c
+++ b/drivers/pci/controller/pcie-cadence-host.c
@@ -102,6 +102,7 @@ static int cdns_pcie_host_init_root_port(struct cdns_pcie_rc *rc)
{
struct cdns_pcie *pcie = &rc->pcie;
u32 value, ctrl;
+ u32 id;
/*
* Set the root complex BAR configuration register:
@@ -121,8 +122,12 @@ static int cdns_pcie_host_init_root_port(struct cdns_pcie_rc *rc)
cdns_pcie_writel(pcie, CDNS_PCIE_LM_RC_BAR_CFG, value);
/* Set root port configuration space */
- if (rc->vendor_id != 0xffff)
- cdns_pcie_rp_writew(pcie, PCI_VENDOR_ID, rc->vendor_id);
+ if (rc->vendor_id != 0xffff) {
+ id = CDNS_PCIE_LM_ID_VENDOR(rc->vendor_id) |
+ CDNS_PCIE_LM_ID_SUBSYS(rc->vendor_id);
+ cdns_pcie_writel(pcie, CDNS_PCIE_LM_ID, id);
+ }
+
if (rc->device_id != 0xffff)
cdns_pcie_rp_writew(pcie, PCI_DEVICE_ID, rc->device_id);