summaryrefslogtreecommitdiff
path: root/drivers/nvme/target/core.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/nvme/target/core.c')
-rw-r--r--drivers/nvme/target/core.c50
1 files changed, 31 insertions, 19 deletions
diff --git a/drivers/nvme/target/core.c b/drivers/nvme/target/core.c
index be6fcdaf51a7..25cc2ee8de3f 100644
--- a/drivers/nvme/target/core.c
+++ b/drivers/nvme/target/core.c
@@ -864,10 +864,9 @@ static inline u16 nvmet_io_cmd_check_access(struct nvmet_req *req)
static u16 nvmet_parse_io_cmd(struct nvmet_req *req)
{
- struct nvme_command *cmd = req->cmd;
u16 ret;
- ret = nvmet_check_ctrl_status(req, cmd);
+ ret = nvmet_check_ctrl_status(req);
if (unlikely(ret))
return ret;
@@ -1118,9 +1117,20 @@ static void nvmet_start_ctrl(struct nvmet_ctrl *ctrl)
{
lockdep_assert_held(&ctrl->lock);
- if (nvmet_cc_iosqes(ctrl->cc) != NVME_NVM_IOSQES ||
- nvmet_cc_iocqes(ctrl->cc) != NVME_NVM_IOCQES ||
- nvmet_cc_mps(ctrl->cc) != 0 ||
+ /*
+ * Only I/O controllers should verify iosqes,iocqes.
+ * Strictly speaking, the spec says a discovery controller
+ * should verify iosqes,iocqes are zeroed, however that
+ * would break backwards compatibility, so don't enforce it.
+ */
+ if (ctrl->subsys->type != NVME_NQN_DISC &&
+ (nvmet_cc_iosqes(ctrl->cc) != NVME_NVM_IOSQES ||
+ nvmet_cc_iocqes(ctrl->cc) != NVME_NVM_IOCQES)) {
+ ctrl->csts = NVME_CSTS_CFS;
+ return;
+ }
+
+ if (nvmet_cc_mps(ctrl->cc) != 0 ||
nvmet_cc_ams(ctrl->cc) != 0 ||
nvmet_cc_css(ctrl->cc) != 0) {
ctrl->csts = NVME_CSTS_CFS;
@@ -1179,19 +1189,19 @@ static void nvmet_init_cap(struct nvmet_ctrl *ctrl)
ctrl->cap |= NVMET_QUEUE_SIZE - 1;
}
-u16 nvmet_ctrl_find_get(const char *subsysnqn, const char *hostnqn, u16 cntlid,
- struct nvmet_req *req, struct nvmet_ctrl **ret)
+struct nvmet_ctrl *nvmet_ctrl_find_get(const char *subsysnqn,
+ const char *hostnqn, u16 cntlid,
+ struct nvmet_req *req)
{
+ struct nvmet_ctrl *ctrl = NULL;
struct nvmet_subsys *subsys;
- struct nvmet_ctrl *ctrl;
- u16 status = 0;
subsys = nvmet_find_get_subsys(req->port, subsysnqn);
if (!subsys) {
pr_warn("connect request for invalid subsystem %s!\n",
subsysnqn);
req->cqe->result.u32 = IPO_IATTR_CONNECT_DATA(subsysnqn);
- return NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
+ goto out;
}
mutex_lock(&subsys->lock);
@@ -1204,33 +1214,34 @@ u16 nvmet_ctrl_find_get(const char *subsysnqn, const char *hostnqn, u16 cntlid,
if (!kref_get_unless_zero(&ctrl->ref))
continue;
- *ret = ctrl;
- goto out;
+ /* ctrl found */
+ goto found;
}
}
+ ctrl = NULL; /* ctrl not found */
pr_warn("could not find controller %d for subsys %s / host %s\n",
cntlid, subsysnqn, hostnqn);
req->cqe->result.u32 = IPO_IATTR_CONNECT_DATA(cntlid);
- status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
-out:
+found:
mutex_unlock(&subsys->lock);
nvmet_subsys_put(subsys);
- return status;
+out:
+ return ctrl;
}
-u16 nvmet_check_ctrl_status(struct nvmet_req *req, struct nvme_command *cmd)
+u16 nvmet_check_ctrl_status(struct nvmet_req *req)
{
if (unlikely(!(req->sq->ctrl->cc & NVME_CC_ENABLE))) {
pr_err("got cmd %d while CC.EN == 0 on qid = %d\n",
- cmd->common.opcode, req->sq->qid);
+ req->cmd->common.opcode, req->sq->qid);
return NVME_SC_CMD_SEQ_ERROR | NVME_SC_DNR;
}
if (unlikely(!(req->sq->ctrl->csts & NVME_CSTS_RDY))) {
pr_err("got cmd %d while CSTS.RDY == 0 on qid = %d\n",
- cmd->common.opcode, req->sq->qid);
+ req->cmd->common.opcode, req->sq->qid);
return NVME_SC_CMD_SEQ_ERROR | NVME_SC_DNR;
}
return 0;
@@ -1311,10 +1322,10 @@ u16 nvmet_alloc_ctrl(const char *subsysnqn, const char *hostnqn,
pr_warn("connect request for invalid subsystem %s!\n",
subsysnqn);
req->cqe->result.u32 = IPO_IATTR_CONNECT_DATA(subsysnqn);
+ req->error_loc = offsetof(struct nvme_common_command, dptr);
goto out;
}
- status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
down_read(&nvmet_config_sem);
if (!nvmet_host_allowed(subsys, hostnqn)) {
pr_info("connect by host %s for subsystem %s not allowed\n",
@@ -1322,6 +1333,7 @@ u16 nvmet_alloc_ctrl(const char *subsysnqn, const char *hostnqn,
req->cqe->result.u32 = IPO_IATTR_CONNECT_DATA(hostnqn);
up_read(&nvmet_config_sem);
status = NVME_SC_CONNECT_INVALID_HOST | NVME_SC_DNR;
+ req->error_loc = offsetof(struct nvme_common_command, dptr);
goto out_put_subsystem;
}
up_read(&nvmet_config_sem);