summaryrefslogtreecommitdiff
path: root/drivers/gpu/drm/i915/i915_gem_clflush.c
AgeCommit message (Collapse)Author
2018-08-17drm/i915: Remove unecessary dma_fence_opsDaniel Vetter
dma_fence_default_wait is the default now, same for the trivial enable_signaling implementation. v2: Also remove the relase hook, dma_fence_free is the default. Reviewed-by: Chris Wilson <chris@chris-wilson.co.uk> Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch> Cc: Jani Nikula <jani.nikula@linux.intel.com> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Cc: Rodrigo Vivi <rodrigo.vivi@intel.com> Cc: Chris Wilson <chris@chris-wilson.co.uk> Cc: Tvrtko Ursulin <tvrtko.ursulin@intel.com> Cc: Colin Ian King <colin.king@canonical.com> Cc: Daniel Vetter <daniel.vetter@ffwll.ch> Cc: Mika Kuoppala <mika.kuoppala@intel.com> Cc: intel-gfx@lists.freedesktop.org Link: https://patchwork.freedesktop.org/patch/msgid/20180704092909.6599-2-daniel.vetter@ffwll.ch
2018-02-16drm: move read_domains and write_domain into i915Christian König
i915 is the only driver using those fields in the drm_gem_object structure, so they only waste memory for all other drivers. Move the fields into drm_i915_gem_object instead and patch the i915 code with the following sed commands: sed -i "s/obj->base.read_domains/obj->read_domains/g" drivers/gpu/drm/i915/*.c drivers/gpu/drm/i915/*/*.c sed -i "s/obj->base.write_domain/obj->write_domain/g" drivers/gpu/drm/i915/*.c drivers/gpu/drm/i915/*/*.c Change is only compile tested. v2: move fields around as suggested by Chris. Signed-off-by: Christian König <christian.koenig@amd.com> Reviewed-by: Chris Wilson <chris@chris-wilson.co.uk> Link: https://patchwork.freedesktop.org/patch/msgid/20180216124338.9087-1-christian.koenig@amd.com Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk>
2017-12-13drm/i915: Allow fence allocations to failChris Wilson
If a fence allocation fails in a blocking context, we will sleep on the fence as a last resort. We can therefore allow ourselves to fail and sleep on the fence instead of triggering a system-wide oom. This allows us to throttle malicious clients that are consuming lots of system resources by capping the amount of memory used by fences. Testcase: igt/gem_shrink/execbufX Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20171212180652.22061-2-chris@chris-wilson.co.uk
2017-10-16drm/i915: Refactor testing obj->mm.pagesChris Wilson
Since we occasionally stuff an error pointer into obj->mm.pages for a semi-permanent or even permanent failure, we have to be more careful and not just test against NULL when deciding if the object has a complete set of its concurrent pages. Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20171013202621.7276-1-chris@chris-wilson.co.uk
2017-08-15drm/i915: Split obj->cache_coherent to track r/wChris Wilson
Another month, another story in the cache coherency saga. This time, we come to the realisation that i915_gem_object_is_coherent() has been reporting whether we can read from the target without requiring a cache invalidate; but we were using it in places for testing whether we could write into the object without requiring a cache flush. So split the tracking into two, one to decide before reads, one after writes. See commit e27ab73d17ef ("drm/i915: Mark CPU cache as dirty on every transition for CPU writes") for the previous entry in this saga. v2: Be verbose v3: Remove unused function (i915_gem_object_is_coherent) v4: Fix inverted coherency check prior to execbuf (from v2) v5: Add comment for nasty code where we are optimising on gcc's behalf. Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=101109 Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=101555 Testcase: igt/kms_mmap_write_crc Testcase: igt/kms_pwrite_crc Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Maarten Lankhorst <maarten.lankhorst@linux.intel.com> Cc: Dongwon Kim <dongwon.kim@intel.com> Cc: Matt Roper <matthew.d.roper@intel.com> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Cc: Mika Kuoppala <mika.kuoppala@linux.intel.com> Tested-by: Maarten Lankhorst <maarten.lankhorst@linux.intel.com> Acked-by: Maarten Lankhorst <maarten.lankhorst@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20170811111116.10373-1-chris@chris-wilson.co.uk Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com>
2017-07-27drm/i915: Force CPU synchronisation even if userspace requests ASYNCChris Wilson
The goal here was to minimise doing any thing or any check inside the kernel that was not strictly required. For a userspace that assumes complete control over the cache domains, the kernel is usually using outdated information and may trigger clflushes where none were required. However, swapping is a situation where userspace has no knowledge of the domain transfer, and will leave the object in the CPU cache. The kernel must flush this out to the backing storage prior to use with the GPU. As we use an asynchronous task tracked by an implicit fence for this, we also need to cancel the ASYNC flag on the object so that the object will wait for the clflush to complete before being executed. This also absolves userspace of the responsibility imposed by commit 77ae9957897d ("drm/i915: Enable userspace to opt-out of implicit fencing") that its needed to ensure that the object was out of the CPU cache prior to use on the GPU. Fixes: 77ae9957897d ("drm/i915: Enable userspace to opt-out of implicit fencing") Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=101571 Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Cc: Jason Ekstrand <jason@jlekstrand.net> Reviewed-by: Jason Ekstrand <jason@jlekstrand.net> Link: https://patchwork.freedesktop.org/patch/msgid/20170721145037.25105-5-chris@chris-wilson.co.uk Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
2017-06-16drm/i915: Store i915_gem_object_is_coherent() as a bit next to cache-dirtyChris Wilson
For ease of use (i.e. avoiding a few checks and function calls), store the object's cache coherency next to the cache is dirty bit. Specifically this patch aims to reduce the frequency of no-op calls to i915_gem_object_clflush() to counter-act the increase of such calls for GPU only objects in the previous patch. v2: Replace cache_dirty & ~cache_coherent with cache_dirty && !cache_coherent as gcc generates much better code for the latter (Tvrtko) Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Dongwon Kim <dongwon.kim@intel.com> Cc: Matt Roper <matthew.d.roper@intel.com> Tested-by: Dongwon Kim <dongwon.kim@intel.com> Cc: Tvrtko Ursulin <tvrtko.ursulin@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170616105455.16977-1-chris@chris-wilson.co.uk Reviewed-by: Tvrtko Ursulin <tvrtko.ursulin@intel.com>
2017-06-16drm/i915: Mark CPU cache as dirty on every transition for CPU writesChris Wilson
Currently, we only mark the CPU cache as dirty if we skip a clflush. This leads to some confusion where we have to ask if the object is in the write domain or missed a clflush. If we always mark the cache as dirty, this becomes a much simply question to answer. The goal remains to do as few clflushes as required and to do them as late as possible, in the hope of deferring the work to a kthread and not block the caller (e.g. execbuf, flips). v2: Always call clflush before GPU execution when the cache_dirty flag is set. This may cause some extra work on llc systems that migrate dirty buffers back and forth - but we do try to limit that by only setting cache_dirty at the end of the gpu sequence. v3: Always mark the cache as dirty upon a level change, as we need to invalidate any stale cachelines due to external writes. Reported-by: Dongwon Kim <dongwon.kim@intel.com> Fixes: a6a7cc4b7db6 ("drm/i915: Always flush the dirty CPU cache when pinning the scanout") Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Dongwon Kim <dongwon.kim@intel.com> Cc: Matt Roper <matthew.d.roper@intel.com> Tested-by: Dongwon Kim <dongwon.kim@intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170615123850.26843-1-chris@chris-wilson.co.uk Reviewed-by: Tvrtko Ursulin <tvrtko.ursulin@intel.com>
2017-05-03drm/i915: Mark up clflushes as belonging to an unordered timelineChris Wilson
2 clflushes on two different objects are not ordered, and so do not belong to the same timeline (context). Either we use a unique context for each, or we reserve a special global context to mean unordered. Ideally, we would reserve 0 to mean unordered (DMA_FENCE_NO_CONTEXT) to have the same semantics everywhere. Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Daniel Vetter <daniel.vetter@ffwll.ch> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170503093924.5320-1-chris@chris-wilson.co.uk
2017-03-23drm/i915: Wait for all fences before installing an exclusive clflush fenceChris Wilson
Ensure that before we overwrite the reservation_object with our exclusive fence for the pending clflush operation, that we do wait upon all the fences in the current reservation_object. Fixes: 57822dc6b9cf ("drm/i915: Perform object clflushing asynchronously") Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Cc: Matthew Auld <matthew.auld@intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170323085758.11695-1-chris@chris-wilson.co.uk Reviewed-by: Mika Kuoppala <mika.kuoppala@intel.com>
2017-02-22drm/i915: Remove 'retire' parameter from intel_fb_obj_flushChris Wilson
Setting retire=true is identical to using origin=ORIGIN_CS, so make the same simplification to intel_fb_obj_flush() as already employed for intel_fb_obj_invalidate(). Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170222114049.28456-6-chris@chris-wilson.co.uk
2017-02-22drm/i915: Perform object clflushing asynchronouslyChris Wilson
Flushing the cachelines for an object is slow, can be as much as 100ms for a large framebuffer. We currently do this under the struct_mutex BKL on execution or on pageflip. But now with the ability to add fences to obj->resv for both flips and execbuf (and we naturally wait on the fence before CPU access), we can move the clflush operation to a workqueue and signal a fence for completion, thereby doing the work asynchronously and not blocking the driver or its clients. v2: Introduce i915_gem_clflush.h and use a new name, split out some extras into separate patches. Suggested-by: Akash Goel <akash.goel@intel.com> Signed-off-by: Chris Wilson <chris@chris-wilson.co.uk> Cc: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Cc: Matthew Auld <matthew.auld@intel.com> Reviewed-by: Joonas Lahtinen <joonas.lahtinen@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/20170222114049.28456-5-chris@chris-wilson.co.uk