summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorRafael J. Wysocki <rafael.j.wysocki@intel.com>2025-02-21 17:57:11 +0100
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2025-02-25 12:19:10 +0100
commit423de5b5bc5b267586b449abd1c4fde562aa0cf9 (patch)
tree6d924b996581777cc17f0438f32fb101d3162ba0
parent4ecaa75771a75f2b78a431bf67dea165d19d72a6 (diff)
thermal/of: Fix cdev lookup in thermal_of_should_bind()
Since thermal_of_should_bind() terminates the loop after processing the first child found in cooling-maps, it will never match more than one cdev to a given trip point which is incorrect, as there may be cooling-maps associating one trip point with multiple cooling devices. Address this by letting the loop continue until either all children have been processed or a matching one has been found. To avoid adding conditionals or goto statements, put the loop in question into a separate function and make that function return right away after finding a matching cooling-maps entry. Fixes: 94c6110b0b13 ("thermal/of: Use the .should_bind() thermal zone callback") Link: https://lore.kernel.org/linux-pm/20250219-fix-thermal-of-v1-1-de36e7a590c4@chromium.org/ Reported-by: Yu-Che Cheng <giver@chromium.org> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> Reviewed-by: Yu-Che Cheng <giver@chromium.org> Tested-by: Yu-Che Cheng <giver@chromium.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Tested-by: Lukasz Luba <lukasz.luba@arm.com> Link: https://patch.msgid.link/2788228.mvXUDI8C0e@rjwysocki.net
-rw-r--r--drivers/thermal/thermal_of.c50
1 files changed, 29 insertions, 21 deletions
diff --git a/drivers/thermal/thermal_of.c b/drivers/thermal/thermal_of.c
index 5ab4ce4daaeb..5401f03d6b6c 100644
--- a/drivers/thermal/thermal_of.c
+++ b/drivers/thermal/thermal_of.c
@@ -274,6 +274,34 @@ static bool thermal_of_get_cooling_spec(struct device_node *map_np, int index,
return true;
}
+static bool thermal_of_cm_lookup(struct device_node *cm_np,
+ const struct thermal_trip *trip,
+ struct thermal_cooling_device *cdev,
+ struct cooling_spec *c)
+{
+ for_each_child_of_node_scoped(cm_np, child) {
+ struct device_node *tr_np;
+ int count, i;
+
+ tr_np = of_parse_phandle(child, "trip", 0);
+ if (tr_np != trip->priv)
+ continue;
+
+ /* The trip has been found, look up the cdev. */
+ count = of_count_phandle_with_args(child, "cooling-device",
+ "#cooling-cells");
+ if (count <= 0)
+ pr_err("Add a cooling_device property with at least one device\n");
+
+ for (i = 0; i < count; i++) {
+ if (thermal_of_get_cooling_spec(child, i, cdev, c))
+ return true;
+ }
+ }
+
+ return false;
+}
+
static bool thermal_of_should_bind(struct thermal_zone_device *tz,
const struct thermal_trip *trip,
struct thermal_cooling_device *cdev,
@@ -293,27 +321,7 @@ static bool thermal_of_should_bind(struct thermal_zone_device *tz,
goto out;
/* Look up the trip and the cdev in the cooling maps. */
- for_each_child_of_node_scoped(cm_np, child) {
- struct device_node *tr_np;
- int count, i;
-
- tr_np = of_parse_phandle(child, "trip", 0);
- if (tr_np != trip->priv)
- continue;
-
- /* The trip has been found, look up the cdev. */
- count = of_count_phandle_with_args(child, "cooling-device", "#cooling-cells");
- if (count <= 0)
- pr_err("Add a cooling_device property with at least one device\n");
-
- for (i = 0; i < count; i++) {
- result = thermal_of_get_cooling_spec(child, i, cdev, c);
- if (result)
- break;
- }
-
- break;
- }
+ result = thermal_of_cm_lookup(cm_np, trip, cdev, c);
of_node_put(cm_np);
out: