summaryrefslogtreecommitdiff
path: root/drivers/md/raid5.c
diff options
context:
space:
mode:
authorMark Brown <broonie@kernel.org>2015-03-26 17:50:42 -0700
committerMark Brown <broonie@kernel.org>2015-03-26 17:50:42 -0700
commit1be38e041f8eaa935f370aa0f34dd7a2fe39b1d8 (patch)
tree2d89734fc831593784bd411be03a1b9649de4c9d /drivers/md/raid5.c
parent6935224da2482a261c786501fbccb1dc4a675225 (diff)
parentbc465aa9d045feb0e13b4a8f32cc33c1943f62d6 (diff)
Merge tag 'v4.0-rc5' into spi-bcm2835
Linux 4.0-rc5
Diffstat (limited to 'drivers/md/raid5.c')
-rw-r--r--drivers/md/raid5.c13
1 files changed, 9 insertions, 4 deletions
diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c
index e75d48c0421a..cd2f96b2c572 100644
--- a/drivers/md/raid5.c
+++ b/drivers/md/raid5.c
@@ -5121,12 +5121,17 @@ static inline sector_t sync_request(struct mddev *mddev, sector_t sector_nr, int
schedule_timeout_uninterruptible(1);
}
/* Need to check if array will still be degraded after recovery/resync
- * We don't need to check the 'failed' flag as when that gets set,
- * recovery aborts.
+ * Note in case of > 1 drive failures it's possible we're rebuilding
+ * one drive while leaving another faulty drive in array.
*/
- for (i = 0; i < conf->raid_disks; i++)
- if (conf->disks[i].rdev == NULL)
+ rcu_read_lock();
+ for (i = 0; i < conf->raid_disks; i++) {
+ struct md_rdev *rdev = ACCESS_ONCE(conf->disks[i].rdev);
+
+ if (rdev == NULL || test_bit(Faulty, &rdev->flags))
still_degraded = 1;
+ }
+ rcu_read_unlock();
bitmap_start_sync(mddev->bitmap, sector_nr, &sync_blocks, still_degraded);